contact

  Product Search


Keyword Search



Quick Links


  TROLL 9500 Instrument Options


The TROLL® 9500 water quality instrument can be customised to suit your application with a variety of sensors.

All instruments ship with a temperature and barometric sensors and the TROLL 9500 instrument can be customised with a combination of replaceable sensors for a variety of environmental and industrial applications.

Communication is via In-Situ RuggedCable using a coms device or simple wiring to an external progeramming / data gathering system. Win-Situ 4 and Flow Sense software helps improve the efficiency of data collection and management.

When building a unit to order, consider the following choices:

  • Do I need logging, or will I be saving data directly to a RuggedReader® handheld PC?
  • Do I need a narrow diameter (less than 2") sonde, or will a 4" diameter sonde be acceptable?
  • Do I need pressure and/or turbidity? At what depths will my instrument be deployed?
  • What other parameters do I need to measure? Parameters available are: pH, pH/ORP, High-range conductivity, low-range conductivity, ISE (ammonia, nitrate, or chloride)

Sondes are configured in one of two configurations (see adjacent images):
- "Sub-2 inch" sonde - Slimline (normal) style
- "Sub-4 inch" sonde - Expanded diameter when when turbidity/and or level sensors are required alongside RDO

For other parts and accessories please go to the following pages:
Troll 9500 Sensors
Communication Devices and Options
RuggedCables
Calibration and Other Solutions

See also our Advisory Sheet Summarising Sensor Options

Go to TROLL 9500 Download Page for:
• Technical Specifications
• Quick Start Guides and Manuals
• Accuracy and Calibration
• Applications and Case Histories
• and more!

or call +44 121 733 7743 today to speak to our technical sales team.

For more details:
Download as PDF



TROLL 9500 Logging Base Units
Choose from a selection of 3 base units incorporating a logging unit within the sonde.

TROLL 9500 LTS
Offers the ability to include level, temperature and one additional Sensor, such as conductivity or dissolved oxygen (RDO), or pH.

TROLL 9500 Professional
Our most popular model, offfering great value for most applications. Allows for several sensors including conductivity/salinity, RDO, ORP, pH, temperature or level.

TROLL 9500 Professional XP
The most capable model offering all the features available on the TROLL 9500 Professional but also supporting XP ("Extended Parameter") sensors including turbidity, ammonium, chloride, or nitrate.

Code Description
I0095000-05 TROLL 9500 Base Unit - LTS  
I0095000-03 TROLL 9500 Base Unit - PROFESSIONAL  
I0095000-04 TROLL 9500 Base Unit - PROFESSIONAL XP  


TROLL 9500 Non-Logging Base Units
Choose from 2 non-logging base units. These can be used with external devices linked by cable for logging purposes (e.g. when used in an industrial plc system or with a laptop of RuggedReader® Handheld PC.

Profiler
Ideal for water quality sampling or profiling. Similar to the TROLL 9500 Professional but excludes memory or logging capabilities.

Profiler XP
Offers the same features as the TROLL 9500 Profiler with the option to use XP sensors.


Code Description
I0095000-01 TROLL 9500 Base Unit - PROFILER  
I0095000-02 TROLL 9500 Base Unit - PROFILER XP  


TROLL 9500 Upgrades
Should you decide to extend the abilities of your TROLL 9500 after purchase - for example by adding logging facities or for extended parameter use, this can be done simply and easily without the need to return your instrument to In-Situ. Several upgrade permutations are possible (see list below). Call us for further details.
Code Description
I0042660 TROLL 9500 Upgrade: Profiler to Profiler XP  
I0042670 TROLL 9500 Upgrade: Profiler to Professional  
I0042680 TROLL 9500 Upgrade: Profiler to Professional XP  
I0042700 TROLL 9500 Upgrade: Profiler XP to Professional XP  
I0042710 TROLL 9500 Upgrade: Professional to Professional XP  
I0044100 TROLL 9500 Upgrade: LTS to Professional  
I0044110 TROLL 9500 Upgrade: LTS to Professional XP  


TROLL 9500 Antifouling Shield
Purchase an optional TROLL 9500 antifouling shield for use in aggressive environments where biofouling or corrosion may be a problem.
Antifouling Shield
Code Description
I0095460 TROLL Shield - TROLL 9500 (sub 4 inch) copper sleeve housing  


RuggedCables
Cable for the TROLL 9500 can be supplied in any specified length (up to a maximum of 210 m, depending on sensors chosen). A 2m cable length is commmonly purchased for shallow surface water monitoring or for groundwater monitoring using a flow cell.

Polyurethane vented cable is commonly used for most applications (though if non-vented sensors are chosen for water level measurements, non-vented cable must be used).

Select a cable below and determine the length required. These are most commonly used with twist lock cable connectors (specified separately in the following section) but can also be supplied with stripped and tinned wires for external process control use.

For more details see In-Situ RuggedCables


Rugged Cable Cross-Sections

Code Description
I0052000-01 TROLL Cable - Polyurethane, Vented - Price per metre  
I0052000-03 TROLL Cable - Polyurethane, Non-Vented - Price per metre  
I0052000-05 TROLL Cable - Tefzel, Vented - Price per metre  


Twist-Lock Cable Connectors
Titanium Twist Lock Connectors are commonly used to attach either vented or non-vented Rugged Cable to In-Situ Instruments and communication devices. Choose cable with twist-lock connectors at both ends for most applications.

See PDf downloadfiel for instructions on connections.
Twist-Lock Connectors

Code Description
I0052000 TROLL Cable Connectors inc Assembly - Twist-Lock/Twist-Lock, Titanium, pair  


TROLL Coms - Cable Connect (Plugs into end of RuggedCable) with USB
Cable connect / USB coms device include a female connector which plugs directly into RuggedCable attached to the logging instrument and with a separate USB cable connection to a PC. All Coms units are supplied with a CD fully loaded with Win-Situ 4 and Win-Situ 5 software and more.

For use with a RuggedReader handheld PC, use an alternative Comms device with RS232 serial interface cable.

For instructions see pdf sheet.

Code Description
I0052500 TROLL Com Bundle USB cable connect and Software CD  
I0052510 TROLL Com Bundle USB direct connect and Software CD  


TROLL Coms - Cable Connect (Plugs into end of RuggedCable) with RS232
Cable connect / RS232 coms device include a male connector which plugs directly into the ends of a RuggedCable attached to a logging instrument and with a separate RS232 cable connection to a PC. All Coms units are supplied with a CD fully loaded with Win-Situ 4 and Win-Situ 5 software and more.

These cables are necessary for use with with a RuggedReader handheld PC.

For instructions see pdf sheet.

Code Description
I0056140 TROLL Com Bundle RS-232 cable connect and Software CD  
I0056150 TROLL Com Bundle RS-232 direct connect and Software CD  


Flow Cells & Accessories
Flow cells are included as standard within the Low Flow kits, but can also be purchased separately. Choose a flow cell to match the sonde configuration (sub-2inch or sub-4 inch). A base plate is recommended for keeping the sonde vertical when used in the field.
Flow Cells
Code Description
I0044710 TROLL 9500 (sub 2 inch) - Flow Cell  
I0057600 TROLL 9500 RDO (sub 4 inch) - Precision Flow Cell  
I0044430 TROLL 9500 - Flow Cell Base Plate  


TROLL 9500 Protective Probe Sleeves (Spares)
An appropriate protective probe sleeve is supplied as standard to match whatever TROLL 9500 body and sensor combination you require. Spares can be purchased separately.
Code Description
I0084270 TROLL 9500 (sub 2 inch) - Stainless Steel sleeve and plug  
I0045260 TROLL 9500 (sub 2 inch) - Stainless Steel Sleeve  
I0045270 TROLL 9500 (sub 2 inch) - Black Delrin Nose cone  
I0084350 TROLL 9500 RDO (sub 4 inch) - Delrin sleeve and plug  


Peli Case
A high capacity wheeled PeliCase for secure and safe storage and transport of a complete TROLL 9500 unit with multiple accessories. There is ample space for calibration solutions, cable, flow cell, rugged reader and more
Peli Case
Code Description
I0044910 TROLL 9500 Pelican Hard Sided Carry Case w/wheels  

© Copyright Waterra 2012 | sitemap | company legal