MiniRAE LITE Portable PID Detector
|
Key features
- Accurate VOC monitoring
- Fastest response time (3 sec)
- Humidity & Temperature compensation
- Easy to maintain and operate
- Three-year lamp warranty
Proven PID technology
The patented sensor provides many unique features including a 3-second response time - the best in the field, a PID range up to 5,000 ppm, AND humidity and temperature compensation.
Designed for Service
These units are built with easy access to the PID lamp and sensor in seconds without the need for any tools! And Waterra can provide an annual or more frequent maintenance and calibration service at very competitive prices.
Rugged Design with the Field User in Mind
These units are built to last and to help you out on site! They include a big graphic display, a field-interchangeable battery pack which is replaceable in seconds without tools, an integrated flashlight for better visibility in low light, a rugged IP67 rated housing which can withstand use in harsh environments and a strong, protective removable rubber boot.
Additional Advantages
Units are loaded with features to help the field user including:
- Duty-cycling™ lamp and sensor auto-cleaning technology
- Tough, flexible inlet Flex-I-Probe™
- Large keys, operable with 3 layers of gloves
- Strong, built-in sample pump can draw from up to 30m horizontally or vertically
- Loud, 95 dB audible alarm
- Bright red flashing visible alarm
- Interchangeable battery packs (rechargeable Lithium-ion or standard alkaline)
- 3-year 10.6 eV lamp warranty
Choosing the Right PID for the Job
For a broader range, higher specification PID See the MiniRAE 3000 or for Benzene specific detection, the UltraRAE 3000. See MiniRAE PID Sheet for a comparison of features across the MiniRAE range.
For more details:
MiniRae Lite Portable PID
|
The MiniRae LITE monitor operates with a standard 10.6 eV UV lamp and comes complete with a range of basic accessories including: operation and maintenance manual, soft leather carrying case, rubber boot (yellow), Flex-I-Probe, external filter (x2), tool kit, lamp cleaning kit and alkaline battery adaptor. Rechargeable Li-ion battery packs are optionally available - including an ATEX certified option. Rechargeable battery packs are supplied complete with a travel charger and a universal AC/DC adaptor / international plug kit with separate serial PC download cable. Download VOC Correction Factors for an explanation and list of correction factors for specific volatile organic compounds. |
|
|
|
|
|||||||||
|
|||||||||||
MiniRae Lite Portable PID with Accessory Kit
|
The MiniRae LITE monitor can be supplied in a rugged field case as part of an enhanced accessory kit which adds the following items to those listed above: Hard transport field case with customised foam insert, 5 porous metal filters and o-rings, organic vapour zeroing kit and gas outlet port adaptor and tubing. Choose optional rechargeable Li-ion battery packs for standard and ATEX applications. |
|
|
|
|
|||||||||
|
|||||||||||
MiniRae PID Travel Charger
|
A lightweight mains travel charger is supplied as standard with all rechargeable battery packs. This unit also includes a serial port connector - used as a means of applying firmware upgrades or for downloading date (from MiniRae 3000 and higher models only). The separate 12V car adaptor cable, which is not supplied with battery pack options, is required for plugging the charger into a 12V outlet in a vehicle. |
|
|
|
|
||||||
|
||||||||
MiniRae PID Charger Cradle
|
A robust mains charging desk cradle for use with rechargeable battery pack options. Can charge an instrument and spare battery pack at the same time. Also includes USB connection for downloading data from MiniRae 3000 units and higher. Included as standard within the MiniRAE 3000 and UltraRAE 3000 accessory kits. Purchase separately for use with MiniRAE Lite. |
|
|
|
|
|||
|
|||||
MiniRae Calibration Gases and Regulators (Steel Cylinders)
|
For calibration of Mini RAE Lite and 3000 PIDs either 100 ppm or 10 ppm Isobutylene gas in air is commonly used. For calibration of the UltraRAE 3000 benzene specific PID, use 5ppm benzene in air. All gases supplied by RAE are contained in 34L steel cylinders. A special hazardous goods charge applies for supply of these items - please ask. For use with 34L steel gas cylinders, RAE supply either a constant flow regulator (CGA600 female thread, 0.5 l/min - Waterra part no: MR/R001) or a higher spec demand flow regulator (CGA600 female thread - Waterra part no: MR/R002), which has an instrument controlled variable flow gas discharge rate. |
|
|
|
|
|||||||||||||||
|
|||||||||||||||||
Other Calibration Gases and Regulators (Aluminium Cylinders)
|
Gases can be sourced from any good scientific gas supplier such as STG (www.stgas.eu) who can supply disposable aluminium gas cylinders in variable sizes. Please note: If using disposable aluminium cylinders, or for gas bottle sizes greater than 34L in aluminium or steel, a flow regulator with male thread is required (C-10 male thread, 1 l/min - Waterra part nos: MR/R004 or MR/R005). |
|
|
|
||||||
|
||||||||
MiniRae PID External Filters
|
Supplied in packs of 5 or 10, these disposable external disc filters (0.45 µm,45mm dia) are an absolute essential when using PIDs to prevent contamination by dust, dirt or moisture (including rain). Filters push fit onto the end of the Flex-I Probe using the (supplied) metal connector. Two external filters are supplied on initial purchase - buy additional filters for ongoing use. |
|
|
|
|
||||||
|
||||||||
MiniRae PID Filter Tubes
|
Disposable filter tubes for better sampling results. For working in high humidity environments, such as landfill sites, use humidity tubes to remove high concentrations of moisture. VOC Zeroing tubes provide a simple means of calibrating the MiniRae instrument to zero by removing background concentrations of VOC in air (e.g in petro-chemical atmospheres). This will provide more accurate and reliable VOC detection from targeted monitoring points or zones. Humidity and VOC tubes are supplied in packs of 10 and require a tube adaptor (Waterra Part no MR/F003) to connect to the tip of the Flex-I-Probe. For benzene measurement use RAE-Sep benzene tubes for high accuracy measurements with the UltraRAE 3000. Supplied in packs of 5. |
|
|
|
|
|||||||||
|
|||||||||||
MiniRae PID Tube Adaptor
Adaptor for connecting 7mm OD tubes onto the end of a Flex-I-Probe. Fits both the zero VOC and humidity filtering tubes. Supplied as part of Accessory kit
![]() Photo shows the tip of the flexiprobe with tube adaptor and filter tube connected. |
|
|
|
|
|||
|
|||||
MiniRae PID Spares and Tools
|
Lamps do become coated over time and regular cleaning with a lamp cleaning kit is essential to retain accuracy. MiniRAE monitors are supplied with a lamp cleaning kit on purchase . Many other spares and accessories are available for all MiniRae products, including the MiniRAE 2000 series. Call us for more information. |
|
|
|
|
||||||||||||||||||
|
||||||||||||||||||||